雙組份打膠機廠家詳解關(guān)于電機線圈失效原因!
時間:2021-07-21 來源:http://intelyalan.cn/ 發(fā)布人:昌盛機械
當(dāng)電機處于非正常工況(包括電氣、機械和環(huán)境方面)時,電機線圈的壽命會嚴(yán)重降低。風(fēng)機盤管故障的原因有:缺相、短路、盤管接地、過載、轉(zhuǎn)子閉鎖、電壓不平衡、浪涌。下面是各種線圈故障,雙組份打膠機可以幫助您正確識別故障原因(以四極電機為例)。
When the motor is in abnormal conditions (including electrical, mechanical and environmental aspects), the life of the motor coil will be seriously reduced. The causes of fan coil unit failure are: lack of phase, short circuit, coil grounding, overload, rotor locking, voltage imbalance, surge. The following is a variety of coil faults, two-component glue machine can help you correctly identify the cause of the fault (take quadrupole motor as an example).
1.新線圈
1. New coil
2.缺相
2. Phase loss
缺相是指電源中某一相的開路。主要原因是一相熔斷器燒斷、接觸器打開或一相電源線斷掉。
Open phase refers to the open circuit of a phase in the power supply. The main reason is that one phase fuse is burnt out, contactor is opened or one phase power line is broken.
在四極電機缺相燒壞的圖片中,電機線圈對稱燒壞的意思是缺相燒壞。當(dāng)缺相導(dǎo)致星形連接燒壞時,2極電機只有2組線圈是好的,4極電機只有4組線圈是好的;如果三角連接缺相燒壞,兩極電機的2組線圈和四極電機的4組線圈是好的。
In the picture of four pole motor with missing phase and burning out, the symmetrical burning out of motor coil means missing phase and burning out. When the star connection is burnt out due to phase loss, only two groups of coils of 2-pole motor are good, and only four groups of coils of 4-pole motor are good; If the delta connection is burned out, the two coils of two pole motor and the four coils of four pole motor are good.
3.短路
3. Short circuit
電機故障是由污染、磨損、振動等原因引起的。
Motor failure is caused by pollution, wear, vibration and other reasons.
4.線圈接地
4. Coil grounding
電機故障是由污染、磨損、振動等原因引起的。
Motor failure is caused by pollution, wear, vibration and other reasons.
5.過載
5. Overload
電機過載會導(dǎo)致電機過載。
Motor overload will cause motor overload.
6.轉(zhuǎn)子鎖定
6. Rotor locking
這種情況會使電機發(fā)熱很多,有可能是由于電機頻繁啟動或頻繁反轉(zhuǎn)。
This situation will make the motor heat a lot, may be due to frequent motor start or frequent reversal.
7.三相不均勻電壓
7. Three phase uneven voltage
電壓不均勻會導(dǎo)致絕緣損壞。原因可能是電源不穩(wěn)定,電線沒有連接好。
Uneven voltage can cause insulation damage. The reason may be that the power supply is unstable and the wires are not well connected.
注意:1%的電壓不平衡將導(dǎo)致6%到10%的電流不平衡。
Note: a 1% voltage imbalance will result in a 6% to 10% current imbalance.
8.飆升
8. Soaring
一般是由浪涌引起的。電涌可能由電網(wǎng)、雷電、電容器和其他電氣設(shè)備引起。
It is usually caused by surge. Surge may be caused by power grid, lightning, capacitors and other electrical equipment.
- 中空玻璃全自動封膠線的優(yōu)缺點是什么 2025/01/07
- 雙組份打膠機出花膠怎樣處理 2025/01/04
- 中空玻璃全自動封膠線一天能做多少平方 2024/12/28
- 中空玻璃生產(chǎn)線一天能做多少平方 2024/12/23
- 全自動丁基膠涂布機操作規(guī)程 2024/12/14
- 丁基膠涂布機在使用的常見問題 2024/12/13
- 雙組份打膠機如何調(diào)整滴膠量? 2024/12/09
- 中空玻璃生產(chǎn)線的磨損如何解決 2024/12/07
- 雙組份打膠機對于打膠工作完成很重要 2024/12/05
- 全自動封膠線的工業(yè)自動化設(shè)備介紹 2024/12/03
產(chǎn)品分類Product categories
聯(lián)系我們Contact us
- 咨詢熱線:0531-85717458 13705446998
- 公司地址: 山東省德州市齊河安頭鄉(xiāng)企巢工業(yè)園
- 掃碼聯(lián)系我們: